Load collective counters for conventional hoistings
![]() |
![]() |
![]() |
Collecting and saving of the operating conditions of hoistings

-
Maximum life time for your hoistings, resulting thus in cost cutting
-
Recording of the working stress / operating conditions
-
Display of the service life
Lifting units for hoistings are designed for a defined load spectrum. The concept for dimensioning and certification is thus designed only for a limited service life.
A load collective counter is used to record the dynamic load in operation as accurately as possible, in order to calculate the used share of the theoretical expected service life. Once the end of this service life is reached according to the counter’s result, a general overhaul has to be made.
Thus the real expected service life of hoistings is largely dependent on the quality of the counting procedure respectfully on the type of the load collective counter.
The calculation is done according to the regulations of the FEM-directive. Due to the exact load measurement and rotation speed recording of our load collective counters the following advantages are achieved:
- Maximum use of the theoretical expected service life of hoistings
- Exact recording and saving of the real working stress/operating conditions
- Continuous calculation and display of the already used service life
- Problem-free use of the operation data for further tasks
By using our load collective counters it is possible to increase the service life of hoistings by approx.. 20-50%.
For configurating and setting up our load collective counter a configuration device or a PC configuration software that runs under Windows is available. These are independent from any LAKO type.
LAKO 1
Standard model for all load capacities
Technical information as download
Technology
Load collective counter LAKO 1 | |
Load capacity: | 0..20 t, 0..50 t, 0..100 t, 0..>100 t |
Incoming signal hoisting power: | 0/4..20 mA |
Rotation speed: | 1 impulse per motor rotation |
Galvanic separation of incoming signals: | Yes |
Power supply: | 230 VAC |
Power input: | ca. 10 W |
Weight: | ca. 3 kg |
Material of housing: | Aluminium die-cast |
Dimensions (WxHxD): | 260x160x90 mm |
Type of protection: | IP54 |
Display of load [tons or kg], rotation speed [1/min] resp. lifting speed [m/min] and used service life [%] |
LAKO 3
Universal compact solution, especially for small cranes,
cost efficient starter model
Technology
Load collective counter LAKO 3 | |
Load capacity: | 0..20 t |
Incoming signal hoisting power: | 0/4..20 mA |
Rotation speed: | 2 digital inputs for rotation speed 1 or rotation speed 2 active |
Galvanic separation of incoming signals: | No |
Power supply: | 24 VDC |
Power input: | ca. 10 W |
Weight: | ca. 1 kg |
Material of housing: | Aluminium powder-coated for top-hat rail mounting |
Dimensions (WxHxD): | smallest dimensions: 100x76x61 mm |
Type of protection: | IP54 |
Display of used service life [%] |
Options for all load collective counters
Apart from the standard execution, a number of additional options are available for an extended use of our load collective counters.
- Hoisting load measurement
- Rotation speed recording
- External hoisting load display (see numeric or alphanumeric displays)
- Display of the already used service life
- Data output via serial interface
- Electronic overload protection
- Electronic slack rope protection
- Recording overload cases
- Function monitoring load collective counter
- Automatc monitoring of the service life limit
- Version KTA